Spark Ignition Control Test
The ignition control module and ignition control module transformer are located in the electronics enclosure behind
the generator base front cover.
PREVIOUS PRODUCTION SHOWN IN Fig. 66
Fig. 66
1. Check for earth ground.
PREVIOUS PRODUCTION SHOWN IN Fig. 67
Fig. 67
2. Check to ensure that all electrical terminal connections on the ignition control module and the igniter are clean
and tight.
3. Verify that the ignition control module and the igniter have good ground wire connections. The igniter mounting
bracket should have good metal to metal contact to its mounting surface.
4. Turn the main power switch on. Make sure LLCO light is on.
5. Check for 24VAC output on the ignition control module transformer.
C24GA AND C24DA SERIES CONVECTION STEAMER - SERVICE PROCEDURES AND ADJUSTMENTS
F35425 Rev. E (0119) Page 36 of 65