C. Allow main burner to light. If main burner does not light within 90 seconds, turn power switch off. Wait 5
minutes before re-lighting.
D. Repeat until main burner lights.
If main burner continues not to light, check AIR PRESSURE SWITCH ADJUSTMENT (ONLY UNITS
WITH ADJUSTABLE PILOT). Adjustment of air pressure switch should only be made when machine cold.
11. Verify manifold gas pressure is 2.5" WC (nat) or 10.0" WC (propane). Adjust pressure setting as necessary
(clockwise to increase, counterclockwise to decrease).
If manifold pressure cannot be set correctly, verify gas supply pressure to machine. If machine has pressure
regulator installed in the supply line to gas valve, perform pressure adjustments.
Blower Air Pressure (HOT)
1. Allow steam generator to operate for at least 15 min. (to verify settings when hot & fine tune if necessary).
2. Disconnect power from machine.
3. Leave power switch on to prevent steam generator from draining.
4. Disconnect 24VAC lead wire from ignition module.
5. Verify manometer reading is zero.
6. Connect power to machine. The blower will turn on but ignition module will not begin sparking to light main
burner.
7. Check blower air pressure .
• Reading should be 0.40" to 0.50" WC (hot). If pressure is not correct, adjust the blower speed
potentiometer to achieve 0.45" WC (clockwise to increase, counterclockwise to decrease).
8. Disconnect power from machine. Leave power switch on to prevent steam generator from draining.
9. Connect 24 VAC lead wire to ignition module.
10. Connect power to machine. Ignition sequence will immediately start and main burner will light. If ignition module
has status LED(s), the ignition sequence can be monitored via LED flash codes.
11. Verify manifold gas pressure did not change.
12. Disconnect power and turn gas supply off. Remove manometer and install pipe plug on gas valve manifold
pressure port.
13. Install blower shroud.
14. Reconnect power and turn gas supply on.
15. Steamer is ready for use.
SOLARONICS BURNER
ADJUSTMENT (STARTING AT
SERIAL NUMBER 463024850)
1. Remove RIGHT SIDE PANEL.
2. Check incoming gas pressure to solenoid valve.
A. Loosen screw with flat head screwdriver (1,
Fig. 46) to open pressure tap.
C24GA AND C24DA SERIES CONVECTION STEAMER - SERVICE PROCEDURES AND ADJUSTMENTS
F35425 Rev. E (0119) Page 24 of 65