Vortex Impact 4000 handleiding
Handleiding
Je bekijkt pagina 7 van 37

12 13
IMPACT
®
4000
MOUNTING
Once your Impact
®
4000 has been calibrated it can be mounted. Prior to mounting the laser rangefinder
ensure your riflescope is mounted and zeroed to your desired zero distance.
1. Mount your picatinny diving board mount or picatinny accessory rail and tighten to the manufacturer’s
torque specifications using a torque wrench.
2. Place the Impact
®
4000 Picatinny Mount on the rail and position it so its placement does not interfere
with the adjustment of the turrets.
3. Using the provided 1/2" Nut Driver Tool, tighten the 1/2" Lug Nuts to 45 in-lbs. Using a torque wrench is
recommended if available.
Note: If the Impact
®
4000 is mounted on the side of the gun, the screen will auto-rotate accordingly.
ZEROING
To ensure the accuracy of the Impact
®
4000 range and ballistic solutions it must be zeroed parallel to
your riflescope. This allows you to aim the device with the center of your reticle at all distances. To zero,
follow the steps below:
1. Before starting, your riflescope must be properly mounted and zeroed. Your Impact
®
4000 must be
calibrated and then mounted.
2. Place the Small Reflective Target Sticker on the Alignment Target at the same measured offset that the
Impact
®
4000 is mounted from the center of the riflescope. Find common mounting offsets marked on
the Alignment Target. Your offset may be different, it is good to measure left/right and up/down offset to
the nearest 1/4" to verify the sticker placement.
Height Over Scope Center = Rangefinder Offset
REFLECTIVE TAPE
REFLECTIVE TAPE
Note: The Alignment Target grid consists of 1" squares for easy measurements.
3. Hang the Alignment Target, in a safe direction, at 50-100 yards using the Large Reflective Tape Strips.
Use one piece of tape on the top of the target and one on the side of the target.
4. Turn the Visible Laser Switch on the side of the laser rangefinder to “Enable” utilizing the provided
Torx
®
T-10 Tool.
5. Turn the Visible Laser ON from the Settings Menu. To do so, press the “Settings” button. Navigate to
and select “Settings”. Navigate to and select “Visible Laser” and select “ON”.
Note: While the Visible Laser is ON, all ranging and ballistic functions are disabled.
6. Utilize the Large Reflective Tape Strips to locate the target with the Visible Laser. The Visible Laser may
not be well aligned to start.
7. Align your riflescope’s crosshair to the center dot of the Alignment Target, and use the Flat Head Tool to
adjust the Elevation and Windage Turrets to align the Visible Laser to the Small Reflective Target Sticker.
8. Your Impact
®
4000 is now zeroed parallel to your riflescope.
9. Turn the Visible Laser Switch on the side of the laser rangefinder to “Disable” utilizing the provided
Torx
®
T-10 Tool and turn the Visible Laser OFF from the Settings Menu following the instructions from
Step 5.
Once the Impact
®
4000 is calibrated, mounted, and zeroed it must be setup to your specifications to
ensure accurate ballistic solutions for your shooting scenario.
SETUP MENU
Changing Modes on the Impact
®
4000
The Impact
®
4000 is factory set to the angle compensating HCD Range Mode, Normal Target Mode, .308
Winchester Profile, and Range Card OFF.
To Change Modes:
Press the “Measure” button to power on the unit, and then press the “Settings” button to open the Main
Menu. Navigate to and select “Setup”. In the Setup screen, you can access both Range and Target Mode
Selection screens.
As you progress through the Mode Selection, you may exit at any time and save your settings by pressing
the “Settings” button and the unit will then return to the Range Ready screen.
Bekijk gratis de handleiding van Vortex Impact 4000, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.