V_VOFF NO-LOAD VOLTAGE. After the load is connected and
operating normally, the device will shut down when the
input voltage reaches the unload voltage setting value.
V_RANGE
VOLTAGE RANGE. The input voltage range supported
by the electronic load is as follows:
Low range: 0-15V
High range: 0-150V
I_RANGE
CURRENT RANGE. The input current range supported
by the electronic load is as follows:
Low range: 0-4A
High range: 0-40A
VON_SET LOAD VOLTAGE. After the load is connected, normal
load operation can occur once the input voltage reaches
the set load voltage.
Figure 4-7-2 parameters setup page
4.8 Multiple Device Parallel Function
The EL-1000 series products can be operated in parallel, supporting up to 10
units, with a maximum current of up to 400A.
Model
Parallel mode
Maximum number of
combinations
Maximum current