Figure 4-7-1 system setup page
4.7.2 Parameter Setting
Select System Settings, then choose Parameter Settings. Press the Enter
key to enter the Parameter Settings options, as shown in the table below.
The parameter settings of the electronic load are as follows:
Menu
Settings
Description
Paramet
er setup
OVP If the input voltage exceeds the set safety threshold (OVP
point), the OVP protection will be triggered.
OCP If the input current exceeds the set safety threshold (OCP
point), the OCP protection will be triggered.
OPP If the input power exceeds the set safety threshold (OPP
point), the OPP protection will be triggered.
SR_RISE RISE SLEW RATE. The setting value for the rise rate of
input voltage or current during load operation.
SR_FALL
FALL SLEW RATE. The setting value for the fall rate of
input voltage or current during load operation.
I_LIM
CURRENT LIMIT. The maximum current value that can
be set for normal load operation.
RComp
REMOTE COMPENSATION. This option allows enabling
the remote sensing function at the rear terminals, with the
default setting for compensation at the front panel input
terminals.