4.2 Local/Remote mode Operation switch
The instrument provides both local and remote operation mode, and the two
modes can be switched by communication commands. In power initialization
mode, the machine is operated locally by default.
Local operation mode: Use the keys on the panel to perform relevant
operations.
Remote operation mode: The instrument is connected to the PC, and the
PC performs relevant operations on the instrument. When the instrument
is in remote mode, all the buttons in the panel do not work except for the
LOCK key. You can switch to local operation mode by press and hold
LOCK key. When the operation mode is changed, it will not affect the
output parameters of the instrument.
4.3 Constant Mode Operation
The electronic load can operate in the following four constant modes:
Constant Current mode (CC)
Constant Voltage mode (CV)
Constant Resistance mode (CR)
Constant Power mode(CP)
4.3.1 Constant Current Mode (CC)
When the user selects the CC function key, the load enters constant current
mode. In constant current operation mode, regardless of changes in the input
voltage, the electronic load consumes a constant current. The relationship
between voltage and current is shown in the figure below.