Vivotek TB9332-E handleiding
Handleiding
Je bekijkt pagina 28 van 88

Thermal Imaging Integrated Network Camera
User Manual
26
Parameter
Description
Setting
Mix Stream Mode
This function is used for mixing
thermal and visible imaging. For
the single thermal camera, it’s
close by default.
[Default value]
Close
3.2 Ambient Temperature
Set the ambient temperature of camera, click “Apply” to save the setting, click
“Refresh” the cavity temperature will be refresh based on ambient temperature.
Ambient Temperature
Parameter of Ambient Temperature
Parameter
Description
Setting
Ambient
Temperature
Environment temperature of
camera.
[Setting method]
Enter the temperature of
the ambient environment.
[Default value]
25
Cavity temperature
Set the ambient temperature, click
“Apply,” and click “Refresh,” and
the camera will get the value
automatically.
[Default value]
The camera will get the
value automatically.
Bekijk gratis de handleiding van Vivotek TB9332-E, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Vivotek |
Model | TB9332-E |
Categorie | Bewakingscamera |
Taal | Nederlands |
Grootte | 10498 MB |