Viking | RVL Steam Oven | MVSOC6301
EN-7
Electrical Requirements
Power Requirements
The oven must be supplied with the proper voltage and frequency. The oven is manufactured to be
connected to a three-wire, single phase, 120/240V, 60 Hz AC electrical supply on a separate circuit fused
in both sides of the line. A circuit breaker or time delay fuse sized not to exceed the circuit rating of the
appliance specified on the rating plate located on the frame behind the door of the oven is recommended.
The oven must be supplied with copper or aluminum wires. If aluminum wire is provided to connect oven
to branch circuit, UL listed connectors for joining copper and aluminum must be used. Follow instructions
provided with connectors.
It is recommended that you have the electrical wiring and hook-up of your oven performed by a qualified
electrician. After installation is complete have the electrician show you where the main disconnect is and
which of the circuit breakers/fuses are for the oven.
Wire sizes and connections must conform with the rating of the appliance and to the requirements of the
National Electrical Code, ANSI/NFPA-70 – latest edition, or Canadian Electrical Code, CSA C22.1-1982 and
C22.2 No. 01982 – latest edition, and all local codes and ordinances.
Oven must be connected to the proper electrical voltage and frequency as specified on the model/serial
rating plate
Ground through the neutral conductor is prohibited for new branch-circuit installation (1996 NEC), mobile homes,
and recreation vehicles, or where local codes prohibit grounding through the neutral conductor. For installations
where grounding through the neutral conductor is prohibited:
Disconnect the ground from the neutral at free end of conduit;
Use grounding terminal or lead to ground unit and usual procedure.
Grounded Neutral
3-Wire branch circuit (for US only)
Where local codes allow the connection of GROUND
wire from the appliance to the branch circuit
NEUTRAL wire (gray or white colored):
If local codes permit, connect the green GROUND
wire from the oven and the white wire from the
oven to the branch circuit NEUTRAL wire (gray or
white colored).
Connect the red and black leads from the appliance
to the corresponding wires from the junction box.
Ungrounded Neutral
4-Wire branch circuit (for US and CANADA)
Connect the green GROUND wire from the oven
to the GROUND wire in the junction box (bare or
green colored wire).
Connect the red and black leads from the oven to
the corresponding wires in the junction box.
Connect the white wire from the oven to the
NEUTRAL (Grey or white colored) wire in the
junction box.
RISK OF ELECTRIC SHOCK
Frame of appliance is grounded to a neutral connection within the appliance.
WARNING