VigilLink VLKV-H2041M handleiding

31 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 23 van 31
20/28
X
und
X
3-pin Phoenix connector
RS-232
USB to RS-232 serial cable
14. RS-232 Command
The product also supports RS-232 command control. Connect the RS-232
port of the product to a PC with a 3-pin phoenix connector cable and an
RS-232 to USB cable. The connection method is as follows.
T
Gro
R
PC
Then open a Serial Command tool on PC to send ASCII commands to control
the product.
The ASCII command list about the product is shown as below.
ASCII Commands
Serial port protocol. Baud rate: 115200 (default)
;
Data bits: 8bit
;
Stop bits:1
;
Check bit: 0
x - Parameter 1
;
y - Parameter 2; ! - Delimiter
Command Code
Function Description Example Feedback
Default
System Setting
help!
List all commands
help!
r type! Get device model
r type!
HDC-SWB41MVK
r fw version!
Get Firmware version
r fw version!
MCU FW version
x.xx.xx
SCALER FW version
x.xx.xx
SUB_MCU FW
version x.xx.xx
KVM_MCU FW
version x.xx.xx
power z!
Power on/off the device,z=0~1
(z=0 power off, z=1 power on)
power 1!
power on
r power!
Get current power state
r power!
power on/power off
reboot!
Reboot the device
reboot!
Reboot…
reset! Reset to factory defaults reset!
Reset to factory
defaults