Encoder Conguration Basic Settings
1. Name: The name of the Encoder can be changed. (The
maximum length is 16 characters. Special characters are not
supported.)
2. Change ID: The ID of the Encoder can be set. (ID range:
1-762)
3. Note: Both ID and name can not be duplicated.
4. Power LED: Click the drop-down menu to select the power
LED ash status.
5. On: The front panel power LED ashes.
6. On 90s: The front panel power LED is steady on after
ashing for 90s.
7. O: The front panel power LED is steady on after ash status
is turned o.
8. Preview: The preview of the Encoder.
A/V Settings
1. EDID: Click the drop-down menu to select the EDID for the
Encoder.
2. Copy EDID: Click the drop-down menu to select a Decoder
for EDID copy.
3. Audio: Click the drop-down menu to select the audio source
(HDMI/ Analogue).
(1)When HDMI is selected, Encoder HDMI input is the audio
source for Encoder HDMI output and Decoder audio output.
(2) When Analogue is selected, Encoder audio input is the
Bekijk gratis de handleiding van VigilLink VLIP-JP1G-CTRL, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.