- 35 / 37 -
Command
Code
Function Description
Example
Feedback Default Setting
Adaptive Feedback Cancellation
s afc hit x!
Select the input, x=1~8
s afc hit 1!
afc hit 1
s afc remove x!
Remove the input, x=1~8
s afc remove 1!
afc remove 1
s afc on!
Enable AFC
s afc on!
afc is active
s afc off!
Disable AFC
s afc off!
afc is unactive
Disable
s afc ans on
level z!
Enable the noise
suppression
function, z=6~18
s afc ans on
level 12!
ans under afc is
active and suppress
noise 12dB
s afc ans off!
Disable the noise
suppression function.
s afc ans off!
ans under afc is
unactive
Disable
Adaptive Echo Cancellation
s aec local hit x!
Select the local input, x=1~8
s aec local hit 1!
aec local hit 1
s aec local
remove x!
Remove the local input,
x=1~8
s aec local
remove 1!
aec local remove 1
s aec ref hit x!
Select the reference signal,
x=1~8
s aec ref hit 3!
aec ref hit 3
s aec ref remove
x!
Remove the reference signal,
x=1~8
s aec ref remove
3!
aec ref remove 3
s aec on nlp z!
Set NLP level, z=1~3
s aec on nlp 2!
aec is active and
nlp set 2
s aec off!
Disable AEC
s aec off!
aec is unactive
Disable
s aec ans on
level z!
Enable the noise
suppression
function, z=6~18
s aec ans on
level 12!
ans under aec is
active and suppress
noise 12dB
s aec ans off!
Disable the noise
suppression function.
s aec ans off!
ans under aec is
unactive
Disable
r aec!
Get AEC status
r aec!
aec is unactive
r aec ans!
Get the noise suppression
status.
r aec ans!
ans under aec is
unactive
Adaptive Noise Suppression
s ans hit x!
Select the input, x=1~8
s ans hit 1!
ans hit 1
s ans remove x!
Remove the input, x=1~8
s ans remove 1!
ans remove 1
s ans on level z!
Set the noise suppression
level, z=6~18
s ans on level
12!
ans is active and
suppress noise
12dB
s ans off!
Disable ANS.
s ans off!
aec is unactive
Disable
r ans!
Get the noise suppression
status.
r ans!
ans is unactive
Equalizer (Output)
s out y peq on
band b on type
z!
Set the filter type,
y=1~8,
b=1~8,
z=1(LP), 2(HP), 5(Peak)
s out 1 peq on
band 1 on type
5!
output 1 peq is
active and set band
1 filter to peak
s out y peq on
band b on frq z!
Set the frequency,
y=1~8,
b=1~8,
z=20~20000
s out 1 peq on
band 1 on frq
1000!
output 1 peq is
active and set band
1 frequency 1000Hz
Bekijk gratis de handleiding van VigilLink VLDT-AP0808, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | VigilLink |
Model | VLDT-AP0808 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 6379 MB |