LOCAL INPUT: The source input channels. You can select the channel based on actual
access conditions. AUTOMIXER refers to mixed signals after the AUTOMIXER process.
ANS LEVEL: The ANS module provides 12 noise suppression levels, ranging from 6dB to
18dB.
ACTIVE: Activates the ANS process. The function is equivalent to clicking the green letter A
at the ANS module on the HOME page.
5.12 Matrix Mixer
The Matrix Mixer allows you to free choose audio route by matrix mode.
As shown below, clicking the MATRIX MIXER section on the HOME page or the MATRIX
tab on the menu bar will enable you to enter the MATRIX MIXER configuration page.
The following figure shows the configuration page in detail.
As shown above, the horizontal line stands for output channels and the vertical for input
channels (except AM, AFC, AEC and ANS).
AM: Indicates the output signal after the ATUO MIXER process.
AFC: Indicates the output signal after the AFC process.
AEC: Indicates the output signal after the AEC process.
ANS: Indicates the output signal after the ANS process.
Fader: Each channel has a fader to control the output volume.