The following figure shows the AFC setting page in detail.
LOCAL INPUT: The source input channels. You can select the channel based on actual
access conditions. AUTOMIXER refers to mixed signals after the AUTOMIXER process.
MAX DEPTH: The maximum amount of gain that the module allows to reduce, with a scale
of [-20.0, 0.0] dB.
BANDWIDTH: The bandwidth of the filter, with Narrow and Wide optional.
RESET: When pressed, the filter will go back to initial settings and the module will re-detect
the frequency point of the acoustic feedback.
FIX BAND: When pressed, fixed values of parameters, such as Frequency, Gain and Width
will be applied to configure the filter in a fixed band. You are allowed to design the filter by
setting its parameters.
FIX ALL: When pressed, all bands will be processed in a fixed mode or in USER-EDITING
mode.
BYPASS BAND: When pressed, the filter of the related band will be disabled.
ACTIVE: Activates the AFC process. The function is equivalent to clicking the green letter A
at the AFC module on the HOME page.
ANS LEVEL: The Adaptive Noise Suppression (ANS) module is provided to suppress
noises with signal level up to 18dB. Clicking the ACTIVE button will give you the option to
activate this function.