1. Remove the refrigerant from the system during maintenance or
scrapping. It is recommended to remove the refrigerant thoroughly.
2. When loading the refrigerant into the storage tank, only a special
refrigerant storage tank can be used. Ensure that the capacity of the
storage tank matches the amount of refrigerant injected in the whole
system. All tanks intended for refrigerant recovery (i. e. special tanks for
refrigerant recovery) shall be equipped with pressure relief valves and
stop valves and in good condition. If possible, the empty tank shall be
vacuum and kept at room temperature before use. Vacuum should be
evacuated and kept at room temperature before use.
3. The recovery equipment shall be kept in good working condition and
equipped with equipment operation instructions for easy inspection. The
equipment shall be suitable for the recovery of R290 refrigerant. In
addition, there should be qualified measurement can be normal use of
weighing instruments. Hoses shall be connected with non-free detachable
joints and remain in good condition. Before using the recovery equipment,
check whether it is in good condition and all electrical parts are sealed to
prevent fire caused by refrigerant leakage. Consult the manufacturer in
questions.
4. The recovered refrigerant shall be installed in the applicable tank with
shipping instructions and returned to the refrigerant manufacturer. Do not
mix the refrigerant in the recovery equipment, especially in the storage
tanks.
5. The area of R290 refrigerant air conditioner loaded during
transportation shall not be closed. If necessary, take anti-static measures
for the transport means. At the same time, in the process of transportation,
loading and unloading of the air conditioner, the necessary protective
measures should be taken to ensure that the air conditioner is not
damaged.
6. When removing the compressor or removing the compressor oil,
ensure that the compressor is evacuated to an appropriate level to ensure
that there is no residual R290 refrigerant in the lubricating oil. Vacuum
performed before the compressor returns to the supplier allows only
electric heating of the compressor housing to speed up this process.
Safety shall be ensured when the oil is discharged from the system.