All maintenance personnel and other personnel in the work area shall be
aware of the nature of the operation undertaken. Working in a confined
space should be avoided. The working area shall be properly isolated to
secure working conditions in the working area.
● Check for the presence of the refrigerant
Appropriate refrigerant monitors shall be used for monitoring within the
area before and during operations to ensure that technicians are aware of
the presence of potentially combustible gases. Ensure that the leak
detection equipment used is suitable for R290 refrigerant such as spark
free, adequately sealed or intrinsically safe.
● The placement of the fire extinguishers
For hot working of the refrigeration system or related components, the
suitable fire extinguisher shall be placed
Nearby
The refrigerant injection area shall be equipped with a dry powder or
carbon dioxide fire extinguisher. Fire sources are prohibited by
In work related to R290 refrigerant, no forms of ignition sources not be
used which may cause a risk of fire or explosion. All fire sources include
smoking. If the R290 refrigerant is likely to be released to the surrounding
environment, it must be far away from the installation, repair, transfer and
disposal areas. Before starting the operation, check the environment
around the equipment to ensure that there is no danger of inflammable or
fire. A "No smoking" mark should be set up.
● Ventilated area (open doors and windows)
Ensure that the work area is open or fully ventilated before the system is
opened or hot processed. Ventilation should be maintained during the
operation. Ventilation quickly discharges the safe ability to dilute the
leaking refrigerant into the atmosphere.
● Inspection of the refrigeration equipment
If the electrical components are replaced, they shall be installed
according to the purpose of use and the correct operation regulations.
Always follow the manufacturer's maintenance and repair guidelines, and
consult the manufacturer's technical department if in doubt. The
following inspection items apply to the installation of the R290 refrigerant
air conditioner
1. The filling amount shall be determined according to the size of the
room containing the refrigerant components;
2. Ventilation equipment should operate normally, and the vents should
be free from obstruction;
3. If an indirect cooling cycle is used, check for the presence of refrigerant
in the secondary circuit;