Save method:
Save at the end of the season
Shut down, unplug the power supply.
Wipe the surface of the machine with a damp cloth, and then dry it with
a dry cloth.
Roll up the power cord with a rope.
Slant the machine slightly to the side with the leakage hole and stand
for half an hour until all the residual condensed water in the machine
flows out.
Cover the machine with plastic bags and put it in a dry place.
Maintenance
WARMMING!
For repair or scrapping,contact a nearby or authorized service
center.Maintenance by unqualified personnel may pose a hazard.
Fill the air conditioner with R290 refrigerant and strictly comply with the
manufacturer's requirements. This section mainly addresses the special
maintenance requirements for using the R290 refrigeration
appliances.
Please refer to, after-sales service manual for detailed service operations.
Qualification requirements for maintenance personnel
All operators or refrigeration system maintenance personnel shall
obtain a valid certificate issued by an industry-recognized evaluation
agency to identify their industry-recognized qualifications for the safe
disposal of refrigerant.
Maintain and repair the equipment only in the manner recommended
by the equipment manufacturer. If other professionals are required to
assist in the maintenance and repair of the equipment, it shall be done
under the supervision of personnel qualified to use R290 refrigerant.
Inspection of the site
Safety checks must be performed before repairing the air conditioner
with R290 refrigerant. When repairing the refrigeration system, follow the
precautions described below before handling the system.
Sequence of operation
Operations shall be performed under a controlled procedure to ensure
that the risk is minimal from combustible gas or steam.
General work area