- 14 -
Power outlet with grounding.
Dry and spacious sundry operating environment, no grease, sharp objects and any
damage to the cable.
Avoid dredging pipes in environments with flammable liquids, dust and steam.
(2) Place the machine 1-2 feet from the pipe entrance, and excessive distance can
cause wire winding.
(3) Ensure that the switch is in the OFF position
(4) Pull out spring from the spring basket, take out the key for
removing the spring from the tool kit, insert into the hole of the spring joint, push
vigorously along the connection groove of the joint, and remove the spring.(as
shown in the figure)
DISMANTLE
(5) Push the parent end of the spring from the front of the machine into the
fuselage, and reserve 1 foot out of the machine. pay attention to: Only one spring
can be removed from the spring basket and pushed into the fuselage. This thin
spring flexible shaft comes with a blade, so there is no need to install a blade.
(6) Select the appropriate dredge head, align the T-groove of the dredge head
joint at the narrow end of the spring joint, push hard, make the tool quickly
connected with the spring joint, check the joint to confirm the connection is tight
(as shown).