Problem
LCD/LED/Buzzer
Explanation /
Possible cause
What to do
Unit shuts down
automatically
during startup
process.
LCD/LEDs and buzzer
will be active for 3
seconds and then
complete off.
The battery voltage
is too low
1. Re-charge battery.
2. Replace battery.
No response after
power on.
No indication.
1. The battery
voltage is far too
low.
2. Battery polarity is
connected
reversed.
1. Check if batteries and
the wiring are connected
well.
2. Re-charge battery.
3. Replace battery.
Mains exist but
the
unit works in
battery mode.
Input voltage is
displayed as 0 on the
LCD and green LED is
flashing.
Input protector is
tripped
Check if AC breaker is
tripped and AC wiring is
connected well.
Green LED is flashing.
Insufficient quality
of AC power.
(Shore or
Generator)
1. Check if AC wires are
too thin and/or too long.
2. Check if generator (if
applied) is working well or
if input voltage range
setting is correct.
(UPS Appliance)
Green LED is flashing.
Set “Solar First” as
the priority of output
source.
Change output source
priority to Utility first.
When the unit is
turned on, internal
relay is switched
on and off
repeatedly.
LCD display and LEDs
are flashing
Battery is
disconnected.
Check if battery wires are
connected well.