TABLE OF CONTENTS Rev. 11/28/2022 EHLT-E MANUAL
TABLE OF CONTENTS Copyright 2022 Vestil Manufacturing Co. Page 15 of 17
TROUBLESHOOTING GUIDE
WARNING
Care should be taken to identify all potential hazards and comply with applicable
safety procedures before beginning work.
Remove any load and install the maintenance props before beginning any inspection
or service on the lift table. See below.
Only qualified individuals trained to understand mechanical devices, electrical and hydraulic circuits, and
the hazards associated with them, should attempt troubleshooting and repair of this equipment.
Consult the factory for any problems not addressed in this manual. ALWAYS have the product serial number
or model number on hand when calling the factory.
PROBLEM
POSSIBLE CAUSES
ACTION
Power unit doesn’t
run when the
(RAISE) button is
pressed.
Transformer fuse is blown.
Test with meter. Replace if bad.
No supply voltage.
Test with meter. Check fuses, breakers, and
overloads to determine the cause
Upper-travel limit switch is engaged or bad.
Inspect and test switch. Replace if bad.
Bad control transformer.
Check for 24 VAC at secondary. Replace if bad.
Bad motor relay coil.
Test with meter. Replace if bad.
Bad solenoid start switch (DC units).
The green LED on motor relay will be off, or will turn
off when the UP pushbutton is pressed.
Battery voltage low (DC units).
Test with meter. Charge battery if low (is the motor
relay LED on?)
Motor runs but
platform doesn’t
move. Power
unit not noisy.
Motor rotation is wrong (AC-powered units
only).
Verify the motor runs CW, opposite the shaft end.
Pump is failing to produce pressure. Contact Technical Service.
Motor hums or
pump squeals,
but the platform
does not move,
or the platform
moves only
slowly.
Pump is failing to produce pressure.
Contact Technical Service.
Excess voltage drop to motor, due to
power wire size too small, wire-run too
long, or incoming voltage too low.
Check the power installation for adequacy. Check
the incoming voltage while the motor is running.
Correct any problems found.
Motor is “single-phasing”.
Determine and correct cause of voltage loss on
phase.
Pressure relief opening at full pressure.
Check for structural damage or binding of the
scissor legs, etc.
Check for platform overload condition.
Contamination holding open the lowering
valve or the check valve.
Remove and inspect valves. Clean per instructions
in the “Inspecting and Maintaining” section.
Platform elevates,
then drifts down.
Contamination holding open the lowering
valve or the check valve.
Remove and inspect valves. Clean per instructions
in “Inspecting and Maintaining” section.
Spongy or jerky
platform
movement.
Excessive air in the hydraulic cylinders.
Bleed air per procedure described in the
“Inspecting and Maintaining
” section.
Platform won’t
lower.
Solenoid coil is bad.
Check with multimeter using the diode-check
function. (Reading for ohms will not provide an
accurate test of the coil). Replace if bad.
Physical blockage of the mechanism.
Inspect for foreign material or objects blocking the
scissors or the rollers.
Solenoid valve, flow control, or suction hose
screen plugged.
Remove and inspect valves. Clean per instructions
in “Inspecting and Maintaining” section.
Platform lowers too
slowly.
Solenoid valve, flow control, or suction hose
screen plugged.
Remove and inspect valves. Clean per instructions
in “Inspecting and Maintaining” section.
Velocity fuse locking (indicated by platform
only slowly creeping down).
Check for air in hydraulic system. Bleed air as
needed.
Flow control valve spool sticking.
Remove and inspect valves. Clean per instructions
in “Inspecting and Maintaining” section.
Platform lowers too
quickly.
Flow control valve spool sticking.
Remove and inspect valves. Clean per instructions
in “Inspecting and Maintaining” section.