Vestil CH-10-12 handleiding
Handleiding
Je bekijkt pagina 6 van 7

Rev. 9/13/2016 CH, MANUAL
Copyright 2016 Vestil Manufacturing Co. Page 6 of 7
Inspections & Maintenance:
Perform all relevant inspections recommended in ASME B30.20. Inspections described below supplement those
described in B30.20.
I. Inspections Before Each Lift -- visually inspect the lifter for structural damage. Structural damage includes, but
is not limited to bending, excessive wear, warping, cracking or other deformation of any part of the coil hook (refer
to FIG. 1 on p. 6; main body frame, especially the lifting bale, handle, or bracket weldment). Restore the coil hook
to normal operating condition before using it again. Remove debris from the hook surfaces.
II. Periodic Inspections: complete visual inspections every 3 months performed AND recorded by a qualified
person.
A. Loose, damaged, or missing hardware (bolts, screws, washers, nuts, pins, etc.). Replace all damaged
and missing hardware. Tighten or otherwise appropriately secure loose connections
B. Excessive wear, particularly at the points where the hook connects to the hoist hook, and load support
clevises or pins. Permanently remove the lifter from service if it cannot be restored to normal operating
condition.
Labeling diagram:
Only use the coil hook if ALL of the labels are readable and undamaged. Contact Vestil for replacement labels.
A: Tag 993 (reverse side) connected to handle
A: Tag 993 (obverse side)
A
B
B: Label 208
Bekijk gratis de handleiding van Vestil CH-10-12, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.