10.REGULAR INSPECTION
Perform the regular inspection for the safety operation
(1) Check the items expressed in daily inspection (daily)
(2) Grease roller guides & grease zerks every month
Roller
Guides
Grease
Zerks
(3) Lubricate wheel axles every 6 months
(4) Replace the hydraulic oil. (Every 12 months)
Do not use brake fluid or jack oil in the hydraulic system. If oil is needed, use an anti-wear hydraulic oil with a viscosity grade
of 150 SUS at 100°F, (ISO 32 @ 40°C), or a non-synthetic transmission fluid.
11.TROUBLE SHOOTING
TROUBLE CAUSE REPAIR
1.Faulty wiring.
1.Check the wiring referring to
the actual wiring diagram.
2.Battery socket is disconnected 2.Connect the battery socket.
Platform does not rise while
motor does not run.
3.Battery charge is insufficient. 3.Charge the battery.
1.Faulty adjustment of relief valve. 1.Adjust relief valve again.
2.Faulty hydraulic pump. 2.Replace power pack.
Platform does not rise while
motor runs.
3.Shortage of hydraulic oil. 3.Add oil.
1.Oil leakage in power pack. 1.Replace lowering valve.
Vertical creep of table.
2.Oil leakage form hydraulic circuit. 2.Check hydraulic circuit and
repair.
Oil leakage from cylinder. Faulty sealing. Replace sealing.
Oil leakage from piping or joint. Insufficient tightening or seal in
valid.
Tighten joint again or Replace
seal.
Oil leakage from air breather. Excessive oil. Reduce oil level.