9.CHARGING THE BATTERY
Warning!
! Working with or near lead acid batteries is dangerous. Batteries contain sulfuric acid and produce explosive gases. A battery
explosion could result in loss of eyesight or serious burns.
! Do not smoke or allow a spark or flame near batteries. Charge batteries in locations which are clean, dry, and well-ventilated. Do
not lay tools or anything metallic on top of any battery. All repairs to a battery must be made by experienced and qualified
personnel.
! When working with batteries, remove personal items such as rings, bracelets, necklaces, and watches. Batteries can produce enough
energy to weld jewelry to metal, causing a severe burn.
! Always have fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes.
! Operating the battery with a low battery voltage can cause premature motor contact failure.
! Do not expose the lift or charger to rain or adverse conditions.
! Replace defective cords or wires immediately.
! Check the battery’s water level frequently if this applies to your battery type.
! Make sure the battery charger is unplugged from 115vac source.
Battery Charger Operating Instructions
Plug the charger into a standard 115V receptacle. If an extension cord must be used, keep it as short and as large as
possible. A small cord will decrease the output of the charger due to the voltage drop in the line. This will increase the
charging time. It can also cause the 115V cord to overheat.
When properly connected, the charge LED will indicate the status of charge current flowing to the battery, as follows:
Power LED is always green when charger is plugged in. The status light is as follows:
Red only – the charger is providing full output to the battery.
Yellow – the charger is “topping off” the battery.
Green – the charger is providing a “float,” or maintenance, charge.
Remember to unplug the charger before moving the equipment. Failure to do so could cause damage to cords,
receptacles and other equipment.
Troubleshooting:
If the unit does not operate, check all of the wiring connections to make sure they’re both mechanically and electrically sound
specifically at the battery, and the motor.
A fully-charged lead acid battery in good condition at room temperature should read 12.65 volts. At 11.9 volts it is considered to be
fully discharged and in need of charging. When checking battery voltage, wait at least 1\2 hour after the charger has been turned off
before checking the batterys voltage.
If the battery isn’t being charged by the charger, check the output charger fuse. Verify fuse is good with an ohmmeter, or
close visual (ohm meter best). Fuse is a 10Amp 250 Volt; GBD 10A. If it is good, check the battery’s state of charge
with a voltmeter. The charger must be connected to the battery in order to read the output voltage of the battery
charger. Depending on the state of charge of the batteries, the voltage should be somewhere around 13.5 volts dc.
If it is determined the battery is dead, and need replaced, change the battery.