Vestel AO-6104 YRS DG handleiding

21 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 14 van 21
EN - 14
with LPG/NG gas. The gas burners can be
adapted to different types of gas, by replacing
the corresponding injectors and adjusting the
minimum flame length suitable to the gas in use.
For this purpose, the following steps should be
performed.
Changing injectors
Hob burners
Cut off the main gas supply and unplug the
appliance from the mains electrical supply.
Remove the burner caps and the adapters.
Use a 7 mm spanner to unscrew the
injectors.
Replace the injector with the ones from the
gas conversion kit, with the correct
diameters for the type of gas that is going
to be used, according to the gas injector
table.
Adapter
Spanner
Injector
Cup
Burner cap
Adjusting the reduced flame position
First of all, make sure that the appliance is
unplugged from the mains electrical supply and
that the gas feed is open. The minimum flame
position is adjusted with a flat screw located on
the valve. For valves with a flame failure safety
device, the screw is located on the side of the
valve spindle as shown in the figures. For valves
without a flame failure safety device, the screw
is located inside the valve spindle as shown in
the figure. T
o make adjusting the flame position
easier, we recommend that you remove the
control panel (and the micro switch if your
model has one) during the alteration.
T
o determine the minimum position, ignite the
burners and leave them on in the minimum
position. With the help of a small screwdriver,
fasten or loosen the bypass screw by around 90
degrees. When the flame has a length of at least
4mm, the gas is well distributed. Make sure that
the flame does not die out when passing from
the maximum position to the minimum position.
Create an artificial wind with your hand towards
the flame to see if the flames are stable.
The bypass screw must be loosened for
conversion from LPG to NG. For conversion from
NG to LPG, the bypass screw must be tightened.
Make sure that the appliance is unplugged from
the mains electrical supply and that the gas feed
is open.
Valve with flame failure device
Bypass screw
Valve with flame failure
device
Bypass
screw
Valve without flame
failure device Bypass
screw (Inside
the hole)
2.3 Changing the Gas inlet
For some countries, the gas inlet type can be
different for NG/LPG gases. In this case,
remove the current connection components
and nuts (if any) and connect the new gas
supply accordingly. In all conditions, all
components used in gas connections should be
approved by local and/or international
authorities. In all gas connections, refer to the
“Assembly of gas supply and leakage check”
clause explained above.
2.4 Electrical Connection
and Safety (if available)
WARNING: The electrical connection of
this appliance should be carried out by an
authorised service person or
qualified electrician, according to the
instructions in this guide and in compliance

Bekijk gratis de handleiding van Vestel AO-6104 YRS DG, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.