3 9471003
The speaker type is selected in the software
during programming, with the choices of 25
Volt, 45 Ohm or Line Level. All speakers must
be of the same type and must not exceed the
following limits:
45 Ohm
Maximum of 5 Valcom 45 Ohm
speakers per zone with no more
than 24 across all zones
25 Volt
Total tap of 15 watts per zone with
no more than 120 watts across all
zones
One-Way
Line Level
Maximum of 45 Valcom self-
amplified speakers per zone and no
more than 240 self-amplified
speakers across all zones
Rear Panel Connections (Figure 1)
Speaker Zones 1 - 24 are individual connectors
for speaker output. A wiring connection block with
screw terminals is provided for each zone. The
individual screw terminal blocks may be removed
for easy installation. Each block has connections
for two zones, with arrows indicating which zone is
the top row and which is the bottom row. The
connections labeled “SW” are not used. Details of
the wiring connections are shown below.
A strain relief bracket is provided to support the
speaker wiring. The bracket must be attached to
the rear of the EZ-GW24 by removing the two case
screws on each end of the unit, positioning the
bracket against the case, and reinstalling the
screws. (Figure 3)
Setup
Information specific to your application will need
to be programmed into the EZ-GW24 using a
computer. The PC used for programming should
be connected to the same subnet as the EZ-
GW24. Setup will be done using the IP Solutions
Setup Tool. Download the latest version of the free
IP Solutions Setup Tool from the Valcom website
at www.valcom.com/vipsetuptool.
Factory Reset Modes
A button is provided through a pinhole in the front
of the EZ-GW24, beside the Status LED, that can
be used to reset the EZ-GW24 configuration.
Pressing the button continuously for 10 to 20
seconds will perform a soft reset on the EZ-GW24.
The IP address will be reset to factory default.
Other configuration items will not be affected.
If the button is pressed for more than 20 seconds,
all configuration items will be reset to factory
default, including the password. (Figure 5)
TECHNICAL ASSISTANCE
When trouble is reported, verify power is being
supplied to the unit and there are no broken
connections. If a spare unit is available, substitute
a spare unit for the suspected defective unit.
Assistance in troubleshooting is available from the
factory. Call (540) 563-2000 and press 1 for
Technical Support or visit our website at
www.Valcom.com.
Valcom equipment is not field repairable. Valcom,
Inc. maintains service facilities in Roanoke, VA.
Should repairs be necessary, attach a tag to the
unit clearly stating your company name, address,
phone number, contact person and the nature of
the problem. Send the unit to:
Valcom, Inc.
Repair & Return Dept.
5614 Hollins Road
Roanoke, Va. 24019-5056
WARRANTY
Warranty information may be found on our website
at www.valcom.com/warranty.