Valcom ezIP EZ-GW1 handleiding
Handleiding
Je bekijkt pagina 3 van 3

3 9471001
AUX
IN
INPUTS
AUDIO CC PAGE
123
4
+24V DC
K1 K2
NO
COM
NC
NC
COM
NO
AUX
OUTPUTS
ON
Network Connection
The EZ-GW1W or EZ-GW1R has one RJ-45
network connector on the front panel. Use a
standard Ethernet patch cable to connect the EZ-
GW1W or EZ-GW1R to an Ethernet switch.
Rear View
Signal Connections
The EZ-GW1W or EZ-GW1R has signal connectors
on the rear panel:
• RCA jack for AUX audio input
• 2 Audio outputs
• 2 Form C relays
• 1 Audio input
• 1 Contact Closure input
AUX Input: Local audio may be input via the rear
panel RCA jack. Nominal input impedance is 600
Ohms. Connect any compatible audio source using
an RCA patch cable. Audio supplied through the
rear panel RCA jack is transformer coupled to both
Audio Out terminals when paging is idle. This is
typically used for background music.
Audio Out: Two audio output connections are
provided. The terminals labeled “Page” provide a
signal output compatible with Valcom self-amplified
speakers. Up to 40 Valcom speakers can be
connected to the Page output. The terminals
labeled “AUX” provide a signal output compatible
with most amplifiers and should be used where a
transformer-coupled output is desired.
DIP Switch: The four-pole DIP switch controls a
supervision signal on the “Page” audio output line.
For systems where supervision is used, setting DIP
switches 1 & 2 to ON enables supervision on the
Page audio output connections. Where supervision
is not used, set DIP switches 1 & 2 to OFF.
Switches 3 & 4 are not used.
Audio Input/Contact Closure: One Audio Input
and one Contact Closure input are provided.
Neither input is polarity sensitive. The contact
closure is labeled "CC". The audio input terminals
are labeled "AUDIO".
Relay Channels: Access to the two form C relays
is provided via a six-pin screw terminal block. The
relays are labeled K1 and K2. Each relay is
brought out on three terminals. The common
contact is the middle terminal with the normally
closed contact on the right and the normally open
contact on the left. Relay contacts are rated for 1A
@ 24Vdc.
Status Indicator Lights
The EZ-GW1W or EZ-GW1R has 3 status
indication lights on the front panel:
STATUS: Flashes during normal operation and
solid during system startup.
Green LED: (Link) Indicates Ethernet connection
when illuminated.
Yellow LED: (Activity) Indicator flashes to indicate
network activity.
SETUP
Information specific to your application will need to
be programmed into the EZ-GW1W or EZ-GW1R
using a computer. The PC used for programming
should be connected to the same subnet as the EZ-
GW1W or EZ-GW1R. Setup will be done using the
IP Solutions Setup Tool. Download the latest
version of the free IP Solutions Setup Tool from the
Valcom web site at www.valcom.com/vipsetuptool.
TECHNICAL ASSISTANCE
When trouble is reported, verify power is being
supplied to the unit and there are no broken
connections. If a spare unit is available, substitute
a spare unit for the suspected defective unit.
Assistance is available from the factory.
Call (540) 563-2000 and press 1 for Technical
Support or visit our website at www.valcom.com.
Warranty
Warranty information may be found on our website
at www.valcom.com/warranty
Valcom equipment is not field repairable.
Valcom, Inc. maintains service facilities in Roanoke,
VA. Should repairs be necessary, attach a tag to
the unit clearly stating your company name,
address, phone number, contact person and the
nature of the problem. Send the unit to:
Valcom, Inc.
Repair & Return Dept.
5614 Hollins Road
Roanoke, Va. 24019-505