* For detailed operations, please refer to the documents accompanying the goods Smart
Dehumidifier User Manual
2.5 Cooling fan
Cooling fanIt is used for heat dissipation in liquid coolers and high-pressure control boxes.
When the internal temperature of the cabinet reaches 30, the fan will start to operate to cool down
the interior of the cabinet.
When the internal temperature of the cabinet drops to 25, the fan stops working.
Figure2-10 Cooling fan
3
F03
Temperature
return
difference
0-40
The factory is set to 5 and the return value is
positive or negative value of temperature. The return
value is 5. In heating mode, setting temperature is 5,
the return value will stop working as long as the
temperature is higher than 10.
4
F04
Humidity
control value
0-100%R
H
Factory setting is 85%RH (0% -100% adjustable)
5
F05
Humidity
return
difference
0-40%RH
The factory is set to 5RH% and the return value is
positive and negative value of humidity. For example,
the humidity is set to 85 and 5 return value will stop if
the humidity is lower than 80%RH.
6
F06
postal
address
1-255
To set the corresponding address of the device, which
is unique throughout the communication bus.
7
F07
Baud rate
1/2/3
Factory Set 3 (1:2400bps 2:4800bps 3:9600bps)