5.1.3 Tools and data
Tools and meters that may be used are shown in table 5-1.
Table 5-1 Tool instrument
NAME
Screwdriver(Slotted、Phillips)
Multimeter
Torque wrench
Clamp current meter
Diagonal pliers
Insulation tape
Pointed nose pliers
Temperature meter
Pliers to hold the wire
Anti-static bracelet
Stripping pliers
Cable tie
Electric drill
Tape measure
5.1.4 Technical preparation
Electrical interface check
Devices that can be connected directly to the battery can be user equipment, power supplies, or other
power supplies.
Confirm whether the user's PV power generation equipment, power supply or other power supply
equipment has a DC output interface, and measure whether the DC power output voltage meets the
voltage range requirements in Table 2-2.
Confirm that the maximum discharge current capability of the DC power interface of the user's
photovoltaic power generation equipment, power supply or other power supply equipment should be
higher than the maximum charging current of the products used in
Table 2-2.
If the maximum discharge capacity of the DC power interface of the user's photovoltaic power
generation equipment is less than the maximum charging current of the products used in Table 2-2,
the DC power interface of the user's photovoltaic power generation equipment shall have a current
limiting function to ensure the normal operation of the user’s equipment.
Verify that the maximum operating current of the battery-powered user equipment (inverter DC
input) should be less than the maximum discharge current of the products used in Table 2-2.
The security check
Firefighting equipment should be provided near the product, such as portable dry powder fire
extinguisher.
Automatic fire fighting system shall be provided for the case where necessary.
No flammable, explosive and other dangerous materials are placed beside the battery.
5.1.5 Unpacking inspection
When the equipment arrives at the installation site, loading and unloading should be carried out
according to the rules and regulations, to prevent from being exposed to sun and rain.
Before unpacking, the total number of packages shall be indicated according to the shipping list
attached to each package, and the case shall be checked for good condition.
In the process of unpacking, handle with care and protect the surface coating of the object.
Open the package, the installation personnel should read the technical documents, verify the list,
according to the configuration table and packing list, ensure objects are complete and intact, if the
internal packing is damaged, should be examined and recorded in detail.