A ALARM PARAMETERS
A0 alarm and fan temperature diff erential C -20 +20 ℉ 2 2
AL low temperature alarm threshold/deviation ( AL= 0 : alarm disabled ) F -50 +250 ℉ 0 0
AH high temperature alarm threshold/deviation ( AH= 0 : alarm disabled ) F -50 +250 ℉ 0 0
Ad low and high temperature alarm delay C 0 199 min 0 0
A4
digital input configuration
0 : input not active
1 : exter. alarm, instant (A7=0) or delayed (A7>0)
2 : enable defrost (open=disabled)
3 : start defrost on closing
4 : curtain switch or night-time operation (open=normal set point)
5 : remote ON/OFF (open=OFF)
6 : AUX output control [H1=3] (open=AUX de-energised)
7 : AUX output [H1=3]+FAN OFF control (closed)(open=AUX energised)
8 : AUX output [H1=3]+FAN OFF control (closed) + COMP. OFF control
(closed) (open=AUX energised)
9 : select direct/reverse operation
r3=0 → open=direct + defrost, closed=reverse
r3=1/2 → open=direct, closed=reverse
10 : condenser probe
11 : product probe
C 0 11 - 0 0
A7 external alarm detection delay C 0 199 Min 0 0
A8 enable alarm ”Ed” : end defrost by timeout (1 = enabled) C 0 1 - 0 0
Ac high condenser temperature alarm C -50 +250 ℉ 150 150
AE high condenser temperature alarm differential C 0.1 20.0 ℉ 10 10
Acd high condenser temperature alarm delay C 0 250 min 0 0
F FAN PARAMETERS
F0 fan management (0 = fans on, 1 = controlled based on parameter F1) C 0 1 - 0 0
F1 evaporator fan control set point F -50 +130 ℃/℉ +5 +5
F2 fans OFF when compressor OFF ( 0=ON , 1=OFF ) C 0 1 - 0 0
F3 evaporator fan status during defrost (0: FAN ON, 1: FAN OFF) C 0 1 - 1 0
Fd post-dripping time F 0 +15 min 2 0
H OTHER SETTING
H0 serial address C 0 199 - 1 1
H1
AUX output confi guration
0 : no function associated with the output
1 : alarm output usually energized
2 : alarm output usually de-energized
3 : auxiliary output driven by digital input [A4=6/7/8]
digital input OPEN = AUX de-energised
digital input CLOSED = AUX energised
C 0 1 flag 1 1
H2 enable keypad (0=disabled, 1=enabled, 2=enabled except for ON/OFF) C 0 2 flag 1 1
H4 disable buzzer (0=enabled, 1=disabled) C 0 1 - 0 0
H5 key ID code from supervisor F -99 +99 - 1 1
EZY select Easy Set according to the model C 0 4 - 1 3