50020-00708 · 00 · 12/2019
Operation Remote indicator DuoC
EN
5 Operation
5.1 Status display
5.1.1 Switching on the status display
Switch the switch (Fig� 2-1) downwards to position
The green (Fig� 2-7) or red (Fig� 2-6) LED on the con-
trol panel is lit and shows the status of the operating
cylinder
Green LED lit
The operating cylinder is full�
Gas is withdrawn from the operating cylinder
Red LED lit
The operating cylinder is empty and the DuoControl CS
has switched over to the reserve cylinder
Gas is withdrawn from the reserve cylinder
5.1.2 Switching off the status display
Switch the switch (Fig� 2-1) to the middle to
position
All LEDs are off
5.2 EisEx
5.2.1 Switching on EisEx
Switch the switch (Fig� 2-1) upwards to position
The yellow LED (Fig� 2-5) on the control panel is lit�
The gas pressure regulator in the gas box is being heat-
ed by the heating cartridge (winter mode)�
The status display is also switched on�
The green (Fig� 2-7) or red (Fig� 2-6) LED on the con-
trol panel is lit and shows the status of the operating
cylinder
5.2.2 Switching off EisEx
Set the switch (Fig� 2-1) to the middle to position
All LEDs are off
The gas pressure regulator in the gas box is not heated�
6 Faults
Below are some measures to remedy faults� If these
measures do not work, contact Truma Service�
Although the remote indicator is switched on, the
LEDs on the control panel are not lit.
Check the 12 V power supply
Check fuses and replace if necessary