Truma DuoC handleiding
Handleiding
Je bekijkt pagina 16 van 64

16
50020-00708 · 00 · 12/2019
Operation Remote indicator DuoC
EN
5 Operation
5.1 Status display
5.1.1 Switching on the status display
Switch the switch (Fig� 2-1) downwards to position �
The green (Fig� 2-7) or red (Fig� 2-6) LED on the con-
trol panel is lit and shows the status of the operating
cylinder�
Green LED lit
The operating cylinder is full�
Gas is withdrawn from the operating cylinder�
Red LED lit
The operating cylinder is empty and the DuoControl CS
has switched over to the reserve cylinder�
Gas is withdrawn from the reserve cylinder�
5.1.2 Switching off the status display
Switch the switch (Fig� 2-1) to the middle to
position �
All LEDs are off�
5.2 EisEx
5.2.1 Switching on EisEx
Switch the switch (Fig� 2-1) upwards to position �
The yellow LED (Fig� 2-5) on the control panel is lit�
The gas pressure regulator in the gas box is being heat-
ed by the heating cartridge (winter mode)�
The status display is also switched on�
The green (Fig� 2-7) or red (Fig� 2-6) LED on the con-
trol panel is lit and shows the status of the operating
cylinder�
5.2.2 Switching off EisEx
Set the switch (Fig� 2-1) to the middle to position �
All LEDs are off�
The gas pressure regulator in the gas box is not heated�
6 Faults
Below are some measures to remedy faults� If these
measures do not work, contact Truma Service�
Although the remote indicator is switched on, the
LEDs on the control panel are not lit.
Check the 12 V power supply�
Check fuses and replace if necessary�
Bekijk gratis de handleiding van Truma DuoC, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Truma |
| Model | DuoC |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 5421 MB |