th models: heated cabinets
www
.truemfg.com
HUMIDIFICATION PROCEDURE
ADJUSTING HUMIDITY
This instruction is TRUE’s recommended procedure for providing
interior humidity control.
The heated cabinet is designed to provide flexibility in desired interior
humidity.
LOW HUMIDITY
A. Positioned in the interior ceiling of the cabinet is the manual
humidity control.
B. Turn counterclockwise to ventilate cabinet humidity.
HIGH HUMIDITY
A. When cabinet contents require higher humidity, fill the 12" x
20" (31 x 51 cm) pan (provided) with water and place in the
bottom of the cabinet.
B. Keep pan full at all times; refilling as necessary.
C. Close the vent described above.
INSTALLING THE VENTILATION CAP
NOTE: Be sure unit is unplugged before proceeding.
A. Remove the ventilator cap, screws and gasket from the plastic
bag located on the inside floor of heated cabinet.
WARNING: Warranty is void if ventilation is insufficient.
B. Position the gasket at the existing ventilation hole on top of
the cabinet. Place the ventilator cap above the ventilation hole
and line up with gasket and mounting holes. Use the screws
provided (4) to secure the ventilation cap.
NOTE: Some cabinets may not include predrilled mounting holes.
In this case use the ventilator cap as a template, center over vent
hole and mark all four hole locations. Drill mounting holes using a
3/32" bit.
PART FUNCTION
TRUE has designed this part to assist in preventing overhead
moisture from entering into the food zone of the cabinet.
VENTILATION CAP
TOP OF CABINET
GASKET