Trotec PAC-C 1500 S handleiding

22 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 10 van 22
10 EN
local air conditioner PAC-C 1500 S
Start-up
During operation, observe the minimum distance to objects as
described in the chapter Technical data.
A
B
C
C
D
Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.
Do not create tripping hazards when laying the power
cable or other electrical cables. Use cable bridges.
Make sure that extension cables are completely unrolled.
Make sure that the air inlet and outlet are not obstructed.
Make sure that no curtains or other objects interfere with
the air flow.
The connection line must not be jammed or kinked.
The connection line must not be subjected to tension or
other mechanical stress.
The pipe insulation and the protective cover must not be
damaged.
Connecting the power cable
Connect the mains plug to a properly secured socket.
Operation
Control panel
21 23 24 25 26 29
31323334
2722 28 3020
No. Designation Meaning
20 Night mode button For switching night mode on or off
21 Fan speed button Setting the fan speed
22 Decrease value
button
For reducing the target temperature
(16°C to 30°C) for cooling
For reducing the number of hours
when programming the timer
23 Fan stage1 LED Illuminated when fan stage1 is
switched on
24 Timer LED Illuminated when the Timer is
activated
25 Segment display Indication of the current room
temperature in dehumidification and
ventilation mode
Indication of the target temperature
in Cooling mode
Indication of the set number of hours
during timer programming
Indication of the error code, see
chapter Errors and faults
26 CoolingLED Illuminated when Cooling mode is
switched on
27 Ventilation LED Illuminated when Ventilation mode is
switched on
28 Increase value
button
For increasing the target temperature
(16°C to 30 °C) for cooling
For increasing the number of hours
when programming the timer
29 Operating mode
button
Setting the operating mode
30 Power button Switching the device on or off
31 WiFiLED Illuminated when WiFi is activated
32 Dehumidification
LED
Illuminated when Dehumidification
mode is switched on
33 Night mode LED Illuminated when night mode is
activated
34 Fan stage2 LED Illuminated when fan stage2 is
switched on

Bekijk gratis de handleiding van Trotec PAC-C 1500 S, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkTrotec
ModelPAC-C 1500 S
CategorieAirco
TaalNederlands
Grootte2784 MB