12 EN
local air conditioner PAC 2020 E / PAC 2620 E
Remote control
All settings of the device can also be made using the remote
control included in the scope of delivery.
Insert suitable batteries in the remote control (seechapter
Technical annex).
Info
After a longer period of non-use, the remote control
will switch to standby mode. Standby mode can be
terminated by pressing the Power button(20) on the
remote control The device automatically uses the
current settings entered via the remote control.
36
20
17
13 33
14
15
30
31
3234
35
No. Designation Meaning
13 Sleep button Switching the Night mode on or off
14 Timer button Switching the timer function on or off
15 Up button Increasing the target temperature for
cooling (16°C to 32°C)
Increasing the number of hours for
the timer function (1hour to 24hours)
17 Downbutton Decreasing the target temperature for
cooling (16°C to 32°C)
Decreasing the number of hours for
the timer function (1hour to 24hours)
20 Power button For switching the device on or off
30 Cooling button Switching the cooling mode on or off
31 Dehumidification
button
Switching the dehumidification mode
on or off
32 Ventilation button Switching the ventilation mode on or
off
33 Temperature unit
button
Changing the temperature unit
between °C and °F
No. Designation Meaning
34 Fan speed1 button Setting fan speed1
35 Fan speed2 button Setting fan speed2
36 Remote control
transmitter/
receiver
Communication between device and
remote control
Switching the device on
1. Leave the device to rest for 24hours if it has previously
been tilted by more than 45°.
2. Once you have completely installed the device as
described in the Start-up chapter, you can switch it on.
3. Press the On/Off button(20).
ð The device switches on and automatically starts in
Ventilation mode.
4. Select the desired operating mode.
The device switches off automatically when the condensation
tank is full. Ft is displayed on the segment display(24).
Setting the operating mode
Cooling
In Cooling mode the room will be cooled down to the desired
target temperature.
1. Press the Mode button(19) until the Cooling LED(23) is
illuminated.
ð Cooling mode is selected.
2. Select the desired target temperature by use of the Up(15)
or Down(17)buttons. Temperatures between 16°C and
32°C can be selected.
ð The target temperature flashes in the segment
display(24).
ð After a short time, the target temperature stops flashing
and the target temperature value is saved.
3. Press the Speed button(18) to set the desired fan stage.
ð The fan stage is indicated on the display(16).
4. Adjust the ventilation flaps on the air outlet by hand(4) to
align the air current.