IV. f - ELECTRICAL REQUIREMENTS/CORD & PLUG:
Traulsen models TBC5 and TBC13 are supplied with a cord
& plug attached. Models TBC1H and TBC1HR require hard
wiring to the power supply, and the 4HP remote condens-
ing unit requires a separate electrical connection of its own.
For your safety and protection, all units supplied with a cord
and plug include a special three-prong grounding plug on
the service cord. Select only a certied electrical outlet with
grounding plug for power source. NOTE: Do not under any
circumstances, cut or remove the round grounding prong
from the plug, or use an extension cord.
A dedicated, grounded circuit should be provided to assure
that the computerized control is not adversely affected by
the operation of other equipment.
Model TBC5 is provided with a NEMA 5-15P cordset.
Model TBC13 is provided with a NEMA L14-20P cordset.
IV. g - PROPER CLEARANCES:
Model TBC5: Make certain that there are no obstructions in
front of the left side louver panel. This will allow for sufcient
air ow to the refrigeration system and maintenance access.
Model TBC13: No rear clearance is required. Allow for 6” on
either side and make certain that there are no obstructions
in front of the louver panel. This will allow for sufcient air
ow to the refrigeration system and maintenance access.
Models TBC1H and TBC1HR: Insure an overhead clearance
of at least 12”. This will allow for sufcient air ow to the
refrigeration system and maintenance access.
IV. h - CONDENSATE REMOVAL:
All Traulsen Blast Chill models (except model TBC5) re-
quire the use of a oor drain or optional electric condensate
evaporator.
Model TBC13 requires either a oor drain or the use of an
optional bottom mounted electric condensate evaporator pan
kit (TBCACC-BMCE) for condensate removal. The drain
port location is at the bottom right of the unit. A receptacle
is provided underneath. See the back cover of this manual
for installation instructions.
Models TBC1H and TBC1HR require either a oor drain or
the use of an optional electric condensate evaporator pan
kit (BCACC-FMCE) for condensate removal. This can be
installed on the chiller through the access panel located front
right at the bottom.
This section applies only to models TBC1H and TBC1HR.
A remote condensing unit, operating on R-404A refrigerant,
is required for Blast Chill operation on these models. The
remote condensing unit should be capable of providing
18,700 BTU/hr @ -10°F evaporator temperature in a 90°F
ambient environment.
IV. INSTALLATION (continued)
-4-
IV. i - REMOTE CONDENSING UNIT REQUIREMENTS:
Both air-cooled and water-cooled remote condensing units
are available from Traulsen as an optional accessory. In-
creased capacity of the remote condensing unit and line
sizing will depend on the length and layout of the connecting
piping from the remote condensing unit to the Blast Chill unit.
Proper line sizing should be dened by a qualied refrigera-
tion engineer or technician.
IV. j - SEALING ROLL-IN/ROLL-THRU UNITS:
This section applies only to models TBC1H and
TBC1HR. Roll-In and Roll-Thru cabinets set on the oor
require the oor area to be at and level. In addition, after
the cabinet is set in place, sealant should be used around
the perimeter of the base to comply with NSF International
requirements. After sealing the unit, the enclosed ramp
should then be installed.
IV. k - ON/OFF SWITCH:
The Traulsen Blast Chiller models are all equipped with a
power ON/OFF switch intended to cut power to the control as
needed. In the event of routine maintenance and/or service
is needed, be certain to disconnect the electrical power to
the machine and follow lockout/tagout procedures.
This is located on top of models TBC1H, towards the rear
on top. On model TBC5, this switch is located in the com-
pressor compartment. On model TBC13 this is located on
the bottom right behind the front louver assembly.
V. l - PRINTER PAPER:
Load printer paper as shown in section “V. c” on page 5.
V. m - CAPACITY:
Pan and approximate maximum product weight capacities
for the individual blast chiller models is as follows:
Pans Product
18” x 26” 12” x 20” Weight
TBC5 5 10 100
TBC13 13 26 200
TBC1H 1 Rack 1 Rack 300
Actual capacity (i.e. weight of product) that can be safely
chilled within FDA guidelines varies greatly depending upon
individual product density and pan loading.