7. MICROPROCESSOR CONTROL (cont’d)
G SERIES
Page 14
7O - SET DEFROST SCHEDULE - MENU SYSTEM: (cont’d)
• Follow the instructions to enter the technician password and Settings submenu.
• Use the Plus Key until the Defrost Time 1 is displayed.
• Press and hold the Enter Key to display the value of the defrost time in the controller.
The Hours will be displayed rst, followed by the Minutes and then the Seconds. Continue to
hold the Enter Key to display all elds in the Date and Time. The elds are identied by the
rst character:
o Hours
o Minutes
o Seconds
• Press the Modify Key and the Hours eld will ash, indicating it is being modied.
• To change a particular Time eld, press the Plus Key or the Minus Key to set the eld to
the desired value.
• When a Time eld is acceptable, press the Enter Key to use the value.
• You must step through all three Time elds to change any one eld.
• When the desired setting is reached, press the Enter Key to lock in the value.
• Use the Plus Key until the Defrost Time 2 is displayed .
• Repeat the steps to program Defrost 2 – Defrost 6
A time of 00:00:00 disables the defrost time (it is not used). To program midnight, enter 24:00:00. The Defrost Times 1 –
6 can be entered in any order. As few as one or as many as six Defrost Times may be entered.
7P - VIEW THE SENSOR TEMPERATURES - MENU SYSTEM:
These parameters allow a service technician or customer to view the temperatures of all sensors within the unit. The tem-
peratures cannot be adjusted. The keypad must be unlocked to access the menu system.
• Follow the instructions to enter the customer password and Sensors submenu.
• Press the Enter Key to enter the Sensors submenu.
• The rst parameter displayed will be the Cabinet Temp (TC = TempCab).
• Press the Enter Key to display the value of the Cabinet Temp.
• Use the Plus Key to move to the next parameter (Evaporator Temp).
• Press the Enter Key to display the value of the Evaporator Temp.
• Use the Plus Key to move through the sensor parameters. The following parameters are available:
o Cabinet Temp
o Evaporator Temp
o Liquid Line Temp
o Dew Point
o Compressor Command
o Evaporator Fan Command
o Condenser Fan Command
o Defrost Heater Command
o Door Heater Command
o Door Switch Status
o Aux Device Command
o Light Command
In General:
• Use the Plus Key and the Minus Key to move through the
Menu System.
• Press the Enter Key to display the value of the selected
parameter.
DISPLAY
SYMBOL
DISPLAY
DESCRIPTION
SEt/Settings
Plus (+)
/Next Key
Defrost Time 1
Enter Key
Hours (value of
defrost trime)
DISPLAY
SYMBOL
DISPLAY
DESCRIPTION
Hours
Minutes
Seconds
DISPLAY
SYMBOL
DISPLAY
DESCRIPTION
Modify Key
Plus (+)
/Next Key
Minus (-)
/Previous Key
Enter Key
DISPLAY
SYMBOL
DISPLAY
DESCRIPTION
Cabinet Temp
Evaporator Temp
Liquid Line Temp
Dew Point
Compressor
Command
Evaporator Fan
Command
Condenser Fan
Command
Defrost Heater
Command
Door Heater
Command
Door Switch
Status
Aux Device
Command
Light Command
DISPLAY
SYMBOL
DISPLAY
DESCRIPTION
Plus (+)
/Next Key
Minus (-)
/Previous Key
Enter Key