Toolson DWS225DC handleiding
Handleiding
Je bekijkt pagina 32 van 296

32
|
GB
10.2 Maintenance
Before and after each use, check the product and ac-
cessories (e.g. tool attachments) for wear and dam-
age. If necessary, replace them with new ones as de-
scribed in this operating manual.
When doing so, observe the technical requirements.
10.2.1 Replacing the grinding plate (Fig. 8.1 - 8.2)
1. Remove the sanding paper (9).
2. Insert the Allen key (15) into the hexagonal hole in
the centre of the grinding plate (8) and turn it clock-
wise to remove the damaged grinding plate (8).
3. Insert the new grinding plate (8) and tighten it
again.
10.2.2 Replacing the carbon brushes
The carbon brushes are wear parts that wear out
during use. The carbon brushes should therefore be
checked regularly. To prevent damage to the circuit,
the two carbon brushes must be replaced at the same
time.
m WARNING!
The carbon brushes may only be replaced by au-
thorised service personnel.
The device must only be used with both carbon
brushes.
10.2.3 Replacing the sanding paper (g. 3)
m WARNING!
Pull out the mains plug!
1. Set the product down on a level surface.
2. Remove the sanding paper (9) from the grinding
plate (8).
3. Fit new/dierent sandpaper (see 8.3).
10.2.4 Replacing the mains connection cable
Have a damaged mains connection cable of the pow-
er tool replaced by the manufacturer or its custom-
er service or a similarly qualied person in order to
avoid hazards.
m WARNING!
There are no parts which can be maintained by the
user within this product. Never open the product!
Take it to a qualied specialist for further mainte-
nance work!
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with designation H05VV-F.
The printing of the type designation on the connection
cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of C 16A or K 16A for machines with a high start-
ing current (from 3000 watts)!
Connection type Y
If the mains connection cable of this device is dam-
aged, it must be replaced by the manufacturer, their
service department or a similarly qualied person to
avoid dangers.
10. Cleaning, maintenance and storage
m WARNING!
Pull out the mains plug before working on the
product itself (e.g. transport, set up, modication,
cleaning and maintenance work)!
10.1 Cleaning
• Keep protective devices, ventilation openings and
the motor housing as free of dust and dirt as pos-
sible.
• Wipe the product clean with a clean cloth or blow it
o with compressed air at low pressure.
• Clean the product thoroughly directly after each use.
• Do not use any cleaning products or solvents, as
they could attack the plastic parts of the device.
Make sure that no water can penetrate the device