Step 1. Press the Emergency Activation switch.
The Emergency indicator (Emergency
Activation switch) lights red and the
VM-3360VA or VM-3240VA is placed in
emergency broadcast mode. The indication
requesting broadcast output selection is
displayed on the LCD.
Step 2. Press the All-Zone Call Selector key or
Output Selector key to select the broadcast
zones.
• Pressing the All-Zone Call Selector key
causes the All-Zone Call indicator to light
green, allowing emergency broadcasts to
bemadeoverallbroadcastzones.
• Pressing the Output Selector key causes
the selected Output indicators to light
green, allowing emergency broadcasts
to be made over the corresponding
broadcastzone(s).
Note
Skipping Step 2 allows emergency
broadcasts to be made over all zones,
as if the All-Zone Call Selector key was
pressed.
Step 3. Press either the Alert or Evacuation Announcement Start key.
The Alert Announcement indicator or Evacuation Announcement indicator and the Emergency Output
indicator both light red, broadcasting the Alert or Evacuation announcement over the selected broadcast
zone(s).
Note
Holding down the Alert Announcement Start key during Alert announcements or the Evacuation
Start key during Evacuation announcements for 3 seconds or more causes the announcement to be
terminated and the indicator to go out.
All-zone Call Selector key
Emergency Activation switch/Emergency indicator
All-zone Call indicator
Alert Announcement
Indicator
Output Selector key
Output indicator
LCD screen
Emergency Output indicator
Evacuation Announcement Start key
Alert Announcement
Start key
Evacuation
Announcement
indicator
[VM-3240VA/3360VA]
Normal status
E
M
E R
G
E N C Y
S E L E C T
O
U T P U T
E
M
E R
G
E N C Y
S E L E C T
O
U T P U T
E
M
E R
G
E N C Y
A L E R T
M
E S S A
G
E
E
M
E R
G
E N C Y
E V A C U A T E
M
E S S A
G
E
Broadcast zone selection
request screen
Broadcast zone selection
request screen
or
1
ALL OUTPUT 1 – 6
2
ALERTEVACUATE
3
EMERGENCY
Alert announcement in progress
Evacuation announcement in progress
6.1.2. Automatic emergency announcement broadcasts
ThisfunctionmakesemergencybroadcastswiththekeyontheVM-3360VA’sorVM-3240VA’sfrontpanelby
playing back the Alert or Evacuation announcements recorded and stored in the VM-3360VA or VM-3240VA.
Bekijk gratis de handleiding van Toa RM-300MF, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Toa |
| Model | RM-300MF |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 19502 MB |
Caratteristiche Prodotto
| Gewicht | 1100 g |
| Breedte | 200 mm |
| Diepte | 82.5 mm |
| Hoogte | 215 mm |
| Kleur behuizing | Wit |