Toa RM-300MF handleiding

150 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 36 van 150
36
Step 1. Press the Emergency Activation switch.
The Emergency indicator (Emergency Activation
switch) lights red and the VM-3360VA or VM-3240VA
is placed in emergency broadcast mode. The
indication requesting broadcast output selection is
displayed on the LCD.
Step 2. Press the All-Zone Selector key or Output Selector
keytoselectthebroadcastzones.
Pressing the All-Zone Call Selector key causes
the All-Zone Call indicator to light green, allowing
emergency broadcasts to be made over all
broadcastzones.
Pressing the Output Selector key causes the
selected Output indicators to light green, allowing
emergency broadcasts to be made over the
correspondingbroadcastzone(s).
Note
Skipping Step 2 allows emergency broadcasts to be made
over all zones, as if the All-Zone Call Selector key was
pressed.
All-zone Call Selector key
Emergency Activation switch/Emergency indicator
All-zone Call indicator
Output Selector key
Output indicator
LCD screen
Emergency
microphone
Emergency Output indicator
Emergency microphone operation indicator
[VM-3240VA/3360VA]
Normal status
E
M
E R
G
E N C Y
S E L E C T
O
U T P U T
E
M
E R
G
E N C Y
S E L E C T
O
U T P U T
Broadcast zone
selection request
screen
Broadcast zone
selection request
screen
or
1
ALL OUTPUT 1 – 6
2
EMERGENCY
6.1. Making Emergency Broadcasts from the VM-3240VA or VM-3360VA
6.1.1. Microphone announcements
Use the emergency microphone located on the front panel of the VM-3360VA or VM-3240VA.