20. Emergency Microphone
After the emergency mode is activated, press the
Talk key located on the side of the microphone
tomakeanall-zonecalloremergencybroadcast
overtheselectedzones(theRM-320Fisrequired
forzoneselection).
If an emergency attention tone* is enabled, a
ding-dong is broadcast when the Press-to-talk
switchispressed.Whethertousetheemergency
attention tone can be selected on the VM-3000
Setting Software. Refer to "10.2. Emergency
Control Input Settings; (2) Emergency attention
tone" in the separate VM-3000 Setting Software
instruction manual.
* This function can be used only when both
versionsofVM-3000VArmwareandVM-3000
Setting Software are 3.00 or later.
21. RM -320F Connector
Connect the RM-320F Fireman’s Microphone
ExtensionUnittothisconnector.
22. DIP Switch
Used to set the unit ID number and equipment
functions. (Refer to "DIP Switch Functions" on
p. 92.)
Switch 1 [MAINTENANCE]
Always set this switch to the OFF position. Default
setting:OFF
(Refer to "Maintenance Mode" on p. 94.)
Note
If this switch is set to ON, the unit is placed in the
maintenance mode and the front panel-mounted
Communication Failure indicator (9) lights green,
causing the unit not to work.
Switches 2, 3
Not used.
Defaultsetting:OFF
Switches 4, 5 [UNIT ID]
SetstheIDnumberoftheFireman’sMicrophone.
Defaultsetting:ON
(Refer to "Unit ID Number Settings" on p. 93.)
Switch 6 [COMPRESSION]
Enables/disablescompression.
Defaultsetting:ON
(Refer to "Compression Settings" on p. 93.)
Switch 7 [TERMINATION]
Sets the RM-300MF Fireman’s Microphone that
functions as a terminating unit.
Defaultsetting:OFF
( Refer to "Setting the Terminating RM-300MF
Unit" on p. 94.)
Switch 8 [CPU OFF]
Enables/disablestheCPUOFFfunction.
Defaultsetting:ON
(Refer to "CPU OFF Function Enable/Disable
Settings" on p. 94.)
23. Relay Connector
Connects to the relay connector (24) of the wall
mount bracket unit (accessory).
24 . Relay Connector
ConnectthecablefromtheRM-300MFFireman’s
Microphone to this connector.
25. Screw Terminal Block
RM Communication Line [DATA (+), DATA (–)]
A control/communication line between the RM-
300MF Fireman’s Microphone and the VM-
3240VA or VM-3360VA.
Audio Output Line [AUDIO OUT H/C]
AudiooutputlinefromtheRM-300MFFireman’s
Microphone to the VM-3240VA or VM-3360VA.
DC Power Supply Input [DC IN 24V +/–]
Power supply line from the VM-3240VA or VM-
3360VAtotheRM-300MFFireman’sMicrophone.
Shield [SHIELD]
Control line used by the VM-3240VA or VM-
3360VA for conrmation of RM-300MF
connections. Ensure that at least one shield is
connected.