53. Functional Ground Terminal
Hum noise may be generated when external
equipment is connected to the unit. Connecting
this terminal to the functional ground terminal of
theexternalequipmentmayreducethehumnoise.
Note: This ground is not for protective ground.
54. Control Output Terminals 1 – 8
[CTRL OUT 1 – 8, G]
Control output terminals for general broadcasts.
Operations assigned to each contact output are
determined by software settings. (For details,
refer to "Event Settings" in the separate software
manual.)
55. Control Input Terminals 1 – 8 [CTRL IN 1 – 8, G]
Control input terminals for general broadcasts.
Functions assigned to each contact input are
determined by software settings. (For details,
refer to "Event Settings" in the separate software
manual.)
56. Audio Input 4 Terminals [INPUT 4]
(VM-3240VA and VM-3360VA only)
Electronically-balanced600Ω,–10dB*/–50dB,
screwterminal.UseDIPswitch(40)forLINE/MIC
switching.
*0dB=1V
57. Remote VOL Terminals 1 & 2 [REMOTE VOL]
Not used.
58. Input 4 Volume Control
(VM-3240VA and VM-3360VA only)
Adjusts the audio input terminal 4’s (56) input
volume.
59.ExternalAmplierLinkConnector[EXT.PA
LINK]
Connects to the VP-2241 or VP-2421 standby
amplier’sPALinkconnector.
60. VM Link Connector [VM Link Out]
ConnectstotheVM-3240E’sorVM-3360E’sVM
Link In connector.
61. LAN Connector [LAN]
(VM-3240VA and VM-3360VA only)
Connects to a PC.
62. Remote Microphone Link Connectors 1 & 2
[RM1 LINK IN, RM2 LINK IN]
(VM-3240VA and VM-3360VA only)
Connect the RM-300MF Fireman’s Microphone
or RM-200M Remote Microphone to these
connectors.
Note
Only one RM-300MF can be connected to each
connector if the system is required to comply with
EN54-16.
63. DIP Switch (VM-3240E and VM-3360E only)
Used for unit ID and equipment settings.
DIP Switches 1 & 2 [LOCAL INPUT]
Notused.Defaultsetting:OFF
DIP Switches 3 – 6 [EXTENSION UNIT NO.]
Used for unit ID settings for the VM-3240E and
VM-3360E. (Refer to "Connections between VM
Ampliers"onp.133 for ID settings.)
Default settings: ON (Switch 3), OFF (Switches
4–6)
DIP Switch 7 [FIRMWARE]
SetthisswitchtoONtoenablermwareversion
updates, and OFF to prohibit the update.
Defaultsetting:ON
DIP Switch 8 [CONFIG]
Not used.
Defaultsetting:ON
64. Local Input Terminals [LOCAL INPUT]
(VM-3240E and VM-3360E only)
Local broadcast can be made when this terminal
is used in conjunction with the Control Input
terminals (55).
(This function can be used only when all the
versions of VM-3000VA rmware, VM-3000E
rmware, and VM-3000 Setting Software are
2.00 or later. For details, refer to "6. SYSTEM
SETTINGS; 6.8. Local Input Setting" in the
separate software instruction manual.).
65. Local Input Volume Control
(VM-3240E and VM-3360E only)
Adjusts the input volume of the equipment
connected to the Local Input terminal (64).
66. LAN Connector [LAN]
(VM-3240E and VM-3360E only)
Not used.
67. VM Link In Connector [VM LINK IN]
(VM-3240E and VM-3360E only)
Connect this connector to the VM-3240VA’s or
VM-360VAs VM LINK OUT connector. When
using two or more VM-3240Es or VM-3360Es,
connect this connector to other VM-3360E’s or
VM-3360E’sVMLINKOUT.
68. Local Remote Microphone Link Connector
[LOCAL RM LINK IN]
(VM-3240E and VM-3360E only)
Not used.
69. PA Link Connector [PA LINK]
Not used.