14
17. VM Reset Key
For the VM-3240VA and VM-3360VA:
Resets the entire system.
For the VM-3240E and VM-3360E:
Resetsonly VM-3240EorVM-3360EExtension
ampliers.
18 . Leve l Me ter
Indicates the output level of the units internal
amplier.
19. Emerge ncy Microphone
Only used while in emergency broadcast
mode. Press the Talk key located on the side
of the microphone to broadcast emergency
announcements.
If an emergency attention tone* is enabled, a
ding-dong is broadcast when the Press-to-talk
switchispressed.Whethertousetheemergency
attention tone can be selected on the VM-3000
Setting Software. Refer to "10.2. Emergency
Control Input Settings; (2) Emergency attention
tone" in the separate VM-3000 Setting Software
instruction manual.
* This function can be used only when both
versionsofVM-3000VArmwareandVM-3000
Setting Software are 3.00 or later.
20. Monitor Speaker
Buzzer tone is audible from this speaker when
the emergency mode is activated by external
equipment other than the unit’s Emergency
Activation switch (5) or when any failure occurs.
21. Emergency Microphone Indicator (red)
Lights when the unit’s front panel-mounted
emergencymicrophone(19)isused.
22. Emergency Microphone Volume Control
Rotate clockwise to increase the emergency
microphone volume.
Rotate counterclockwise to decrease the
emergency microphone volume.
23. Reset Key [RESET]
For emergency broadcasts:
Terminates the emergency broadcast and returns
operation to the original general broadcast.
For general broadcasts:
Resetsthefrontpanel’soutputselectionstatus.
24. Alert Announcement Start Key [ALERT]
For emergency broadcasts:
Plays recorded Alert announcements through the
speaker output selected with the Output Selection
key (33). Holding down this key for 3 seconds
stops the broadcast.
For general broadcasts:
UsedtotestLEDindicators.(Whilepressed,LED
indicatorsremainlitandtheunitsinternalbuzzer
sounds.)
25. Alert Announcement Indicator (red)
Remains lit while a recorded Alert announcement
is being broadcast.
26. Failure Indicator (yellow) [GENERAL FAULT]
(VM-3240VA and VM-3360VA only)
Flashes when a failure occurs while sounding the
internalbuzzer.Pressingthe[OK]key(7)stopsthe
buzzerandswitchestheindicatorfromashingto
steady ON. Failure details are displayed on the
LCD(11).(Whentherearemultiplefailures,they
canbecheckedbymovingthescreenusingthe[+]
key(10)or[–]key(8)).Failuresarenotdisplayed
on the LCD when in setting mode. Failures are
displayed or notied after exiting the setting
mode. Also, if any failure occurs during general or
emergency broadcasts, the operation status and
failure display are alternately shown on the LCD.
27. CPU Failure Indicator (yellow) [CPU FAULT]
Lights when the CPU fails.
28. All-Zone Call Selection Key [ALL]
Simultaneously selects all speaker outputs for
general and emergency broadcasts. Press again
to reset the simultaneous selection.
Whenpressed,allspeakeroutputvolumecontrols
do not work in both general and emergency
broadcast modes.
29. All-Zone Call Indicator (green) [ALL]
Lightswhenanall-zonecallisinitiated.
30.
Speaker Output Volume Controls [OUTPUT 1 – 6]
Adjusttheoutputvolumeofspeakeroutputs1–6.
31. Emergency Broadcast Output Indicators (red)
[EMERGENCY]
Indicate the speaker outputs for emergency
broadcasts.
32. Selected Output Indicators (green) [SELECT]
Indicate the speaker outputs selected with the
Output Selection key (33).
33. Output Selection Keys
Select corresponding speaker output.
Press again to reset the selection.
For general broadcasts:
Selectandresetbroadcastzones.
For emergency broadcast:
Select and reset speaker outputs for emergency
broadcasts made by the unit’s front panel-
mounted emergency microphone and automatic
announcements.

Bekijk gratis de handleiding van Toa RM-300MF, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkToa
ModelRM-300MF
CategorieNiet gecategoriseerd
TaalNederlands
Grootte19502 MB

Caratteristiche Prodotto

Gewicht1100 g
Breedte200 mm
Diepte82.5 mm
Hoogte215 mm
Kleur behuizingWit