3-12
Chapter 3
OPERATION
3.2.RemoteMicrophoneOperationExample
Theemergencymodecannotonlybeactivatedandrestoredfromtheconnectedrealarmsystem,butalso
from any Remote Microphone set for emergency/general-purpose operation.
Here, the settings of the Fireman's Microphone RM-200SF installed on GF of Building A are used as an example
toexplaintheowfromemergencymodeactivationtoitsrestoration.
[SettingContentsofFireman'sMicrophone]
FIREMAN'S MICROPHONE
RM-200SF
RM-200SF
1
2
3
4
5
For instructions on assigning functions to function keys, see the separate Setting Software Instructions,
"EVENT SETTINGS."
Key Setting Function
(1) Emergency Broadcast Pattern
Start
Activates emergency mode and recalls emergency sequence
patterns.
[Pattern contents]
Phase 1: Alert message; all zones; 5 minutes
Phase 2: Evacuation message; all zones; continuous
(2) Emergency Sequence Phase Shift Shifts the phase of the sequence pattern currently being
broadcast to the next phase.
(3) Emergency Reset
(Restoration message)
Broadcast is restored from emergency to normal (general-
purpose) broadcast mode after Restoration message
announcement completion.
(4) All-Zone Call Selects all zones.
(5) Press-to -Talk Makes microphone announcements.