Renewable Energy Lab
INTRODUCTION TO THE COMPONENTS
3
A. The EMS (green energy management
system) is a device capable of transmitting
and monitoring electrical power. It can
measure voltages ranging from 0.01 to 30
volts (V) and currents from 0 to 999
milliamperes (mA). It features two input
terminals and one output socket at the top.
When two easy wire connectors are
connected to the two input terminals
separately, the device measures the
combined voltage of both (series
connection). However, if both easy wire
connectors are connected to the same input
terminal, the device measures the higher
voltage of the two (parallel connection).
B The angle of the 45V solar panel can be adjusted according to the position of the light source. It converts
solar energy or the energy from a 60-watt halogen lamp into electricity, simulating the power generation
process of a solar power plant.
The generator/motor can switch between
generator () or motor (M) modes using a
switch. In generator mode, rotating the axle
generates electricity, simulating the power-
generation process of a hydroelectrc power
plant or fossl fuel plant In motor mode, the
axle rotates simply when electricity is supplied.
Additionally, the generator/motor features a gear
ratio switch, allowing you to switch between two
gear ratios: 35X and 70X.
• Toggle the switch to turn on
the GEMS. Please turn off
the power after use.
• Avoid touching the screen. Use a microfiber cloth to gently wipe off dust
and dirt.
• Both Input Sockets 1 and 2 can be used. When both sockets have power
input, the displayed voltage value will be the sum of both.
• To activate the output socket, turn on the output switch. The current
value will only be displayed when there is power consumption.
• The 4.5V solar panel can
be adjusted to 11 different
angles, in 18° intervals.
• The plug and socket are
compatible and can be
used simultaneously.
• Applicable range: 0V–4.5V.
C
• When switching between 35X and 70X,
push until you hear a “click”; switch to
the left for 35X and to the right for 70X.
• Sockets 1 to 3 are interconnected and
can be used simultaneously.
• Motor mode applicable voltage: 0V–20V.
Seres
connecton
Parallel
connecton
Voltage (Volts)
Input
Socket 1
Input
Socket 2
Low Battery
Indicator
Output Socket
Output Switch
Current (Amps)
Power Switch
of the GEMS
Micro:bit
Connector
Battery Cover
Screw
ON OFF
A
B
Plug Socket
Socket 3
Socket 1
Socket 2
35X / 70X Mode Switch
Cross
Axle
Hole for strap Mode Switch (Motor/
Generator)
35X 70X
35X 70X
Before each experiment, determine whether you will
be using motor mode or generator mode. Motor mode
is represented by and generator mode is
represented by .