Properties of the logger and the software
2.1 Functional scope of the logger
The loggers 100/110 have the following properties:
Temperature (internal) with a resolution of up to 0.1 ° C / ° F
Humidity (only 110) with a resolution of 0.1% RH
Connection for external temperature sensor (via the USB connector)
internal logger clock with date/ time
Up to 60,000 records with intervals of 1 sec to 24 hours
Display of Min / Max / Avg values via the Mode button or automatically
Limit value monitoring and display via the LED and the beeper
Start and stop via
a) Start/Stop button
b) Time indication
c) Duration or record number
Power saving functions
2.2 Functional scope of the software
The software is used to set the logger operating parameters, to read out and archive the recorded
data and display the operating status. The following functions are available:
2.2.1 Logger settings:
Read and set the real time clock in the logger
Display of the battery‘s charge state
Read and set the recording interval
Configure the memory (record number/circular memory)
Start and stop the recording
Start indications: time/button/Reed relay (option)/immediate startup and protection against
multiple startup
Stop indications: time/duration/record number/button/Reed relay (option)/endless (circular
memory)
Set the limit values and their handling (LED/beeper), alarm delay, alarm accumulation
Activate the external sensor
Units °C or °F
Power saving settings for the LCD display, the LEDs and the beeper
Update intervals for the LCD display, the LED flashes and the beeper
Button lock for the Mode button
Entry of up to eight user-defined names
2.2.2 Logger status:
Overview of the hardware and the logger ID
Overview of the operating status of the logger
Log entries of the limit value exceedings and the errors occurred
Overview of all the parameters available in the logger
2.2.3 Records: