18 19
Safety Classication Internal power source.
Designed for continuous use.
No special moisture protection.
Software version Controller: R3_00
Probe: R3_00
Environmental specications
Operating conditions Temperature range: +5°C to +40°C
Humidity: 15% to 90% RH non-
condensing
Atmospheric pressure: 700hPa to
1060hPa
Storage conditions Temperature range: -25°C to + 60°C
Humidity: 15% to 90% RH non-
condensing
Atmospheric pressure: 700hPa to
1060hPa
Note:Theelectricalspecicationsarenominalandsubjectto
variationfromthelistedvaluesduetonormalproduction
tolerances of at least 5%.
Note:Atleast30minrequiredforthedevicetowarm/coolfrom
the minimum / maximum storage temperature between uses until
it is ready for intended use.
Programme parameters
Prog 1 -
Stress
2 -
Urge
3 -
Mixed
4 -
Tone
5 -
Pain
Ramp Up &
Down (s)
1 Constant Constant
/ 1
2 Constant
Plateau (s) 5 Constant
/ 5
3
Rest (s) 10 Constant
/ 10
6
Duration
(min)
20 20 20 20 Continuous
Symbols Table
TYPEBFAPPLIEDPART:Equipmentprovidingadegreeof
protection against electric shock, with isolated applied
part.Indicatesthatthisdevicehasconductivecontactwith
the end user.
Thissymbolontheunitmeans“Refertoinstructionsforuse”.
Temperature Limitation: indicates the temperature limits to
whichthemedicaldevicecanbesafelyexposed.
Humidity Limitation: indicates the humidity limits to which
themedicaldevicecanbesafelyexposed.
Atmospheric Pressure: indicates the atmospheric limits to
whichthemedicaldevicecanbesafelyexposed.
Lot Number: indicates the manufacturer’s batch code so
thatthebatchorlotcanbeidentied.
Serial Number: indicates the manufacturer’s serial number
sothataspecicmedicaldevicecanbeidentied.
Catalogue Number: indicates the manufacturer’s
cataloguenumbersothatthedevicecanbeidentied.
Do not dispose in household waste.
Manufacturer Symbol
Date of Manufacture: indicates the date which the medical
devicewasmanufactured.Thisisincludedwithintheserial
numberfoundonthedevice(usuallyonthebackofthe
device),eitheras“E/Year/Number”(YY/123456)or“E/Month/
Year/Number” (MM/YY/123456).
CE Mark
MedicalDevice
Thismedicaldeviceisindicatedforhomeuse.