To enable remote web management:
1. Launch a web browser from a computer that is connected to your NOVA network.
2. Enter tendawifi.com.
A login window displays.
3. Enter the login password.
The password is case-sensitive.
4. Go to More > Advanced > Remote Web Management.
5. Turn on Remote Web Management.
6. Select Specified IP Address in Remote IP Address field.
ā Any IP Address: Indicates that hosts with any IP address from the internet can access the
web UI of the router. It is not recommended for security.
ā Specified IP Address: Only the host with the specified IP address can access the web UI of
the router remotely. If the host is behind a NAT router, ensure that the IP address is the
WAN IP address (a public IP address) of the NAT router.
7. Enter the IP address that is allowed to access the web UI remotely for Specified IP Address,
which is 210.76.200.101 in this example.
8. (Optional) Specifies the port of the mesh device which is opened for remote management.
The port from 1 to 1024 has been occupied by familiar services. It is strongly recommended to
enter a port from 1025 to 65535 to prevent conflict.
9. Click Save.