Taurus Roner Clip 360 handleiding

64 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 9 van 64
TROUBLE SHOOTING
Noise
Under the normal operation the system will hum due to the motor, impeller and
cooling fan in operation.
Grinding noise
The stainless steel skirt is loose. Push the stainless skirt up into the guide groove
and turn to the right until you hear a click. With the skirt secure, the noise will go
away.
There also might be the chance the stirring shaft was inadvertently bent. In
this case, unscrew the bottom pump disk and gently push the impeller until it is
centered.
Slurping noise
Your pump has created a swirl of water, similar to emptying a bathroom sink or
bathtub. Add more water or gently disturb the water with a spoon. There is no sure
way to eliminate a vortex caused by the pump’s rotation, but it will usually go away
on its own.
Gurgling + whoosh noise
The pump is sucking air - add more water. You should also see small bubbles in
your tank.
Food damage
The pump’s water jet is cracking eggs or damaging sh llets: Turn the pump outlet
to face the container wall; this will greatly temper the ow of the pump output. It is
also good practice to bag eggs to prevent them from being “blown” around in certain
containers.
System will not turn out Check power plug and breakers
Low water level alarm
Add more water, the water level can be dropped during operation by the pump due
to water turbulences
Low water level alarm turns on
after a few seconds of operation
Add more water – The pump generates “waves” – sometimes these waves
will cause the water level at the sensors to uctuate up and down. The waves
sometimes drop the water level right under the sensor and will cause a low water
alarm. This is normal and you just need to add more water.
Temperature read does not match
thermometer
“Sous vide” circulators are calibrated to a scientic platinum primary standard which
is far more accurate than store thermometers.
Lights in house are slightly
ickering when system is on
This is normal as the circulator is modulating power.
SPECIFICATIONS
Model VC1200XD
Thermal Power 1200 watts
Minimum Temperature +20°C
Maximum Temperature +90°C
Temperature Stability ±1%
Minimum water depth 4.25” (11 cm)
Minimum vessel size 2.6 gallons (10 litres)
Maximum vessel size 4.0 gallons (15 litres)
Pump Volume 2.25 gallons/minute (8.5 litres/minute)
Input Power 220 ~ 240 VAC, 50/60 Hz

Bekijk gratis de handleiding van Taurus Roner Clip 360, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkTaurus
ModelRoner Clip 360
CategorieNiet gecategoriseerd
TaalNederlands
Grootte5927 MB