© 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / ametekesp.com 19
ii. Real-time display of 8 electrical parameters
Line Voltage: AC RMS Volts Line-Neutral (Line1-Line2)
Load Current Draw: AC RMS Amps
Load Power Draw: Watts
Neutral-Ground Voltage: AC RMS Volts Neutral-Ground (Line2-
Ground)
Line Frequency: Hertz
Load Power Factor
Line Voltage Crest Factor
Energy Usage (kWh) of connected equipment since date and
time of last manual usage reset
iii. Number of recorded power quality events
Surge Events: SG
Overvoltage Events with turn off of connected equipment: OVoff
Overvoltage Events with no turn off of connected equipment:
OVrec
Undervoltage Events with no turn off of connected equipment:
UVrec
Undervoltage Events with turn off of connected equipment: UVoff
Power Outage Events: PO
b. Scope Mode
i. The Scope Mode enables a real-time voltage, current, and power
oscilloscope which incorporates many functions available in standalone
oscilloscopes. 4kHz Oscilloscope Bandwidth.
ii. Ch1-Ch3 buttons toggle waveform displays.
Ch1 button toggles line voltage trace.
Ch2 button toggles load current trace.
Ch3 button toggles load power trace.