Plumbing Requirements
Locate the water supply line within the shaded area shown
in the illustration below. The water supply line should be
connected to the house supply with an easily accessible
shut-o valve. Do not use self-piercing valves. The water
supply line must not interfere with the installation of the
anti-tip brackets.
A reverse osmosis system can be used provided there is
constant water pressure of 35–120 psi
(2.4–8.3 bar) supplied
to the unit at all times. A copper line is not recommended
for this application.
Installation must comply with all applicable plumbing codes.
3" (76)
18" (457)
6" (152)
RIGHT SIDE
OF OPENING
AREA EXTENDS
1
/2" (13)
FORWARD ON FLOOR
Water supply location
PLUMBING REQUIREMENTS
Water Supply ⁄" OD copper, braided stainless
steel, or PEX tubing
Pressure 35–120 psi (2.4–8.3 bar)
Excess Line for Connection 36" (914)
Classic Series Refrigeration