14 | Sub-Zero Customer Care 800.222.7820
Electrical Requirements
Locate the electrical supply within the shaded area shown
in the illustration below. A separate circuit servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
Installation must comply with all applicable electrical codes.
75
1
/2" (1918)
FROM FLOOR
7"
(178)
E
6"
(152)
RIGHT SIDE
OF OPENING
Electrical supply location
ELECTRICAL REQUIREMENTS
Electrical Supply 115 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Classic Series Refrigeration