Structural Concepts Oasis FSIB4R handleiding
Handleiding
Je bekijkt pagina 22 van 30

22
GENERAL CLEANING SCHEDULE - HONEYCOMB AIR DIFFUSERS (SERVICE TECHNICIANS ONLY)
1. Honeycomb Air Diffuser Removal
• Honeycomb air diffuser cleaning is to be
performed quarterly.
A. Wedge a non-metallic device of suitable strength
(such as a ballpoint pen) between the honeycomb
and the end panel.
Caution! Use care not to dislodge the heating wire
(that prevents condensation on the lamp assembly).
B. Apply pressure to collapse the honeycomb to
allow it to be pulled out of honeycomb retainer.
C. Carefully pry downward and away from the
honeycomb retainer. Clean honeycomb with warm
water and soap solution. Submerse if necessary.
C
D
F
Use brush to dislodge stubborn or sticky residue.
Dry by using vacuum’s blow mode (vs. suction mode).
2. Honeycomb Air Diffuser Installation
D. Squeeze honeycomb to allow it to fit into the
honeycomb retainer.
E. Carefully slide honeycomb into place.
F. Adjust honeycomb so that it fits flat against
retainer. It must not be wavy or out of position.
Note: For honeycomb air diffusers in other locations,
these same general instructions apply.
E
B
Honeycomb
Air Diffuser
A
Illustration Shown Reflects
Remote Unit Only. It May Not
Exactly Reflect Every Feature or
Option of Your Particular Case.